SAP公司間STO裡發貨單過賬後觸發的IDoc報錯 – Could not find code page for –
SAP公司間STO裡發貨單過賬後觸發的IDoc報錯 – Could not find code page for receiving system –
如下的交貨單80000786是公司間STO的外向交貨單。按照設定,這個交貨單過賬後會觸發一個輸出型別,自動產生IDoc然後觸發收貨方的內向交貨單。
該交貨單完成PGI之後,輸出型別ZZIB成功的輸出了,IDoc也產生了,但是出現報錯,如下圖示:
Error occurred while IDoc '0000000000004067' was being sent
Message no. EA076
Diagnosis
The IDoc '0000000000004067' created was to be sent. An error occurred : 'Could not find code page of target system'.
Procedure
Check the current status of the IDoc. The IDoc may already have been sent (repeat send attempt). If the IDoc has still not been sent properly, please inform your system administration.
使用事務程式碼BD87看這個IDoc的內容和狀態,
Could not find code page for receiving system
Message no. E0266
Diagnosis
For the logical destination S4DCLNT1001, you want to determine the code page in which the data is sent using RFC. This was not possible at the current runtime. For this reason, the IDoc could not be sent.
The reason was issued.
Procedure for System Administration
The following detailed information was transmitted as the cause of the problem:
Further possible causes include:
1. The target system could not be accessed at runtime.
2. No logon language or explicit code page is maintained in the destination.
在事務程式碼WE21找到這個RFC的destination S4DCLNT1001,
把上面的Unicode選項卡里勾選‘Unicode’選項,然後重新process idoc,則成功了,
-完-
寫於2021-11-19
來自 “ ITPUB部落格 ” ,連結:http://blog.itpub.net/69946223/viewspace-2843092/,如需轉載,請註明出處,否則將追究法律責任。
相關文章
- 通過IDoc DESADV來實現公司間STO場景中外向交貨單過賬後自動觸發內向交貨單的功能
- SAP RETAIL 寄售模式公司間STO收發貨過賬後的觀察AI模式
- SAP 公司間STO場景中外向交貨單過賬後自動觸發內向交貨單功能的實現
- SAP公司間STO流程裡外向交貨單PGI後自動觸發內向交貨單的實現
- SAP MM 公司間STO裡交貨單PGI之後自動觸發內向交貨單功能的實現
- SAP MM公司間STO裡的交貨單自動建立?
- SAP MM 公司間退貨STO的交貨單PGI報錯 -Purchase order 4500000773 does not -
- SAP MM 公司間STO裡外向交貨單與內向交貨單裡序列號對應關係
- SAP MM 公司間退貨STO流程後勤部分簡述
- SAP 公司間STO發貨單輸出報錯 - 合併工廠AUC1和儲存位置6002沒有貨物收貨地點 -
- SAP MM 維護公司間STO報錯-No delivery type defined for supplying plant-
- SAP MM公司間STO裡的一步法轉庫?
- SAP MM STO單據的外向交貨單建立後新加ITEM?
- MySQL建立觸發器時報錯Error Code: 1064MySql觸發器Error
- SAP 對STO的交貨單執行PGI,報錯 -Fld selectn for mvmt type 643 acct 400020 diff
- SAP MM 可以通過STO在公司間轉移質檢庫存?
- cmake報錯CMake Error: Could not find CMAKE_ROOTError
- SAP UB型別的STO能自動建立交貨單?型別
- SAP RETAIL 如何確定自動補貨觸發的單據型別AI型別
- SAP IDoc 報錯- Function module not allowed SPEIDOC_INPUT_DESADV1 –Function
- SAP RETAIL 通過分配表建立UB STO單據AI
- SAP RETAIL 通過自動補貨功能觸發採購申請AI
- SAP RETAIL 如何確定自動補貨觸發的單據型別 IIAI型別
- SAP RETAIL 如何確定自動補貨觸發的單據型別 IIIAI型別
- iOS開發_Xcode15打包報錯 rsync error: some files could not be transferred (code 23) at /AppleInternaliOSXCodeErrorAPP
- 引入第三方庫報錯Could not find method apt() for argumentsAPT
- SAP 資料更新的觸發
- 在SAP C4C裡觸發SAP ERP的ATP check和Credit check
- SAP RETAIL 通過自動補貨功能觸發的採購申請有些啥特殊的地方?AI
- 執行flutter run命令報錯::ERROR: Could not connect to lockdownd, error code -17FlutterError
- 「SAP技術」 SAP 操作,彈出報錯 - 已根據規則拒絕伺服器觸發的操作 -伺服器
- SAP MM 使用兩個STO實現免關稅跨國公司間轉儲
- SAP MM VL32N收貨過賬報錯 - 系統狀態 HUAS 是活動的 - 之對策
- SAP 異常現象之同一個IDoc可以被POST兩次觸發2張不同的物料憑證
- SAP MM UB型別的退貨STO流程簡述型別
- 除錯觸發器除錯觸發器
- SAP QM 採購訂單收貨時沒有Vendor CoA就不讓收貨過賬的實現
- SAP MM 使用兩個STO實現免關稅跨國公司間轉儲(II)