HP-UX 修改disk instance號

wangbinneuq發表於2015-10-28
1.可以在2臺主機上透過scsimgr -p get_attr all_lun -a hw_path -a device_file -a wwid來檢視wwn,wwn一致的為同一個盤,也可以透過它與儲存劃得每個lun對應起來
2.透過ioinit來修改,具體過程如下:

備份先:備份ioconfig及ioscan的輸出

更改過程
# ioscan –funNCdisk

Class I H/W Path Driver S/W State H/W Type Description
===================================================================
...
disk 17 64000/0xfa00/0xb esdisk CLAIMED DEVICE HP EF0300FATFD
/dev/disk/disk17 /dev/rdisk/disk17
現在要將disk17改為disk28,因為我僅僅是要修改一個disk,所以就直接vi一個infile檔案,如果disk比較多,ioscan加awk來做
#cat infile
64000/0xfa00/0xb disk 28
這裡的64000/0xfa00/0xb是ioscan裡面的disk17的H/W Path
# ioinit -f infile
# ioscan -funNCdisk
Class I H/W Path Driver S/W State H/W Type Description
===================================================================
.....
disk 28 64000/0xfa00/0xb esdisk CLAIMED DEVICE HP EF0300FATFD
/dev/disk/disk17 /dev/disk/disk28 /dev/rdisk/disk17 /dev/rdisk/disk28
# rmsf /dev/disk/disk17
# rmsf /dev/rdisk/disk17

# ioscan -funNCdisk
Class I H/W Path Driver S/W State H/W Type Description
===================================================================
...
disk 28 64000/0xfa00/0xb esdisk CLAIMED DEVICE HP EF0300FATFD
/dev/disk/disk28 /dev/rdisk/disk28

主機重啟後disk instance number不會發生變化

來自 “ ITPUB部落格 ” ,連結:http://blog.itpub.net/14012827/viewspace-1817479/,如需轉載,請註明出處,否則將追究法律責任。