IBM小型機內建RAID更換故障硬碟

woshishui11211發表於2014-03-16

 

一、    現象描述

?  一臺IBM小型機,帶RAID卡,內建3塊硬碟,做RAID5,無熱備

?  2塊硬碟亮黃色故障燈

 

二、    做好rootvg備份(mksysb)和資料備份(強烈建議)

備份完資料後,為了安全,停止應用對硬碟的訪問

 

 

三、    故障確認

?  執行lsdev Cc pdisk/hdiskerrpt命令檢視系統是否有硬碟報錯

?   diag->Task selection -> RAID Array Manager ->

IBM SASDisk Array Manager ->List IBM SASDisk Array configuration檢查raid資訊和pdisk 的狀態

hdisk0    0B-08-ff-0,0  Degraded    RAID 5 Array     484.2GB

 pdisk0   0B-08-00-5,0  Failed      Array Member     242.8GB

 pdisk1   0B-08-01-5,0  Active      Array Member     242.8GB

 pdisk2   0B-08-00-3,0  Active      Array Member     242.8GB

?  用以下操作再次確認硬碟槽位資訊:

Diag->Task Selection->RAID Array Manager->IBM SASDisk Array Manager-> Diagnostics and Recovery Options->SCSI and SCSI RAID Hot Plug Manager-> Identify a Device Attached to a SCSI Hot Swap Enclosure Device

選擇對應的硬碟,按F7確認硬碟所在的槽位(磁碟的黃燈在閃爍)

 

四、    進行磁碟更換

1)     hot plug把硬碟更換,操作如下:

diag?

Task Selection?

RAID Array Manager?

IBM SASDisk Array Manager?

   Diagnostics and Recovery Options?

         SCSI and SCSI RAID Hot Plug Manager?

Replace/Remove a Device Attached to an SCSI Hot Swap Enclosure Device

 

把故障硬碟更換,回車

clip_image001

然後按F3回到上一層選單

       SCSI and SCSI RAID Hot Plug Manager

         Configure Added/Replaced Devices

2)     更換硬碟後,回到

diag->

Task selection ->

         RAID Array Manager ->

IBM SASDisk Array Manager ->

        List IBM SAS Disk Array configuration

可以看到pdiskX的狀態是failed,比如下圖:

3)   hdisk0    0B-08-ff-0,0  Degraded    RAID 5 Array     484.2GB

4)   pdisk0   0B-08-00-5,0  Failed      Array Member     242.8GB

5)    pdisk1   0B-08-01-5,0  Active      Array Member     242.8GB

6)    pdisk2   0B-08-00-3,0  Active      Array Member     242.8GB

7)     lsdev Cc pdisk是可以看到pdisk0available

五、    RAID進行重建

diag->

Task selection ->

       RAID Array Manager ->

IBM SASDisk Array Manager ->

           Reconstruct a IBM SASDisk Array

選擇新產生的磁碟pdisk0進行重建(146GB HDD大概需要4小時)

重建有進度顯示,可以退出重建在後臺執行

clip_image003

 

六、    重建完畢後,確認RAID的狀態為optimal

diag->

Task selection ->

          RAID Array Manager ->

IBM SASDisk Array Manager ->

       List IBM SASDisk Array configuration

clip_image005

 

七、    確認硬碟沒問題,啟動應用

來自 “ ITPUB部落格 ” ,連結:http://blog.itpub.net/26217983/viewspace-1122511/,如需轉載,請註明出處,否則將追究法律責任。