EMC powerpath: 安裝第三個Node掛載共享磁碟時LUN名稱變化的問題

tolywang發表於2009-04-04
Linux AS3.0 + Oracle9.2.0.4  RAC , 兩節點, OCFS  , DELL6650 ,  EMC CX500 Storage   
原來安裝的兩個節點劃了兩個LUN , 用命令檢視分別是  emcpowere , emcpowerf ,  

今天安裝第三個節點,是同樣的兩個lun(有共享data files) ,在節點3上表現為 emcpowerb , emcpowerc .  
不知道後續重新啟動會不會再變化  ?  






原來的節點1,2 上的顯示 :

[root@dmdii-node1 root]# powermt  display  dev=all
Pseudo name=emcpowere
CLARiiON ID=CK200054902666
Logical device ID=60060160E16B1700646BE068E88BDA11
state=alive; policy=CLAROpt; priority=0; queued-IOs=0
==============================================================================
---------------- Host ---------------   - Stor -   -- I/O Path -  -- Stats ---
### HW Path                 I/O Paths    Interf.   Mode    State  Q-IOs Errors
==============================================================================
  1 QLogic Fibre Channel 2300 sda        SP A1     active  alive      0      0
  1 QLogic Fibre Channel 2300 sdc        SP B1     active  alive      0      0
  2 QLogic Fibre Channel 2300 sde        SP A0     active  alive      0      0
  2 QLogic Fibre Channel 2300 sdg        SP B0     active  alive      0      0

Pseudo name=emcpowerf
CLARiiON ID=CK200054902666
Logical device ID=60060160E16B1700656BE068E88BDA11
state=alive; policy=CLAROpt; priority=0; queued-IOs=0
==============================================================================
---------------- Host ---------------   - Stor -   -- I/O Path -  -- Stats ---
### HW Path                 I/O Paths    Interf.   Mode    State  Q-IOs Errors
==============================================================================
  1 QLogic Fibre Channel 2300 sdb        SP A1     active  alive      0      0
  1 QLogic Fibre Channel 2300 sdd        SP B1     active  alive      0      0
  2 QLogic Fibre Channel 2300 sdf        SP A0     active  alive      0      0
  2 QLogic Fibre Channel 2300 sdh        SP B0     active  alive      0      0