SAP BW: 系統連線遇到的一些問題

leniz發表於2011-11-17
         QAS是直接從Product做Client Copy出來的,所以遇到諸多問題。
       
A.  Transfer structure prefix for source system T90CLNT090 is not defined
            我啟用DSO的時候出現以上錯誤。   從網上找到了解決的方法:

1. Go to WE20 and check whether Partner profile T90CLNT090 exist in LS type,if not just add Parnter profile with same and save.

Partner profile Name: T90CLNT090
TYPE: LS

Give:
Ty: US
User: UserName (用你的使用者名稱就可以了)
Lang: EN

and Save.

2. Again re-click on Partner Profile: T90CLNT090
you will see ,there will be some entries in Inbound & out Bound Tabs.

Delete the following from outbound:
1.RSRQST

Delete the following from inbound.
1.RSINFO
2.RSSEND

and save your partner profile.

3. now execute - RSA1, it will ask to active Workbench. Just activate it .

之後可以順利啟用了。


B . Errors have been reported in Business Information Warehouse during IDoc update:
Could not find code page for receiving system

    從R/3抓取資料時,出現如上錯誤。  
1. RSA13進入到source system介面
2. 選擇出現錯誤的源系統
3. 選擇 Restore(恢復)
4. 按照指示操作,就可以恢復了。

中途,出現Ports:A000000002 錯誤,我就按照某個指示,通過WE21 在節點:Transactional RFC下 ,把它給刪了,結果check 資料來源系統的時候,出現無法找到ports,我只好重建,問題來了,這個是流水號, 02已經走過了,自動生成了到A000000004, 後來查詢到可以用 OMSL 可以修改Number Range的範圍,我就把當前流水號重置為1,結果順利生成原來02的流水號了。

另外系統有一個非常重要的表:RSBASIDOC (Assignment of source systems to BIW systems incl. IDoc type),  這個表會儲存,系統之間通過IDoc連線的一些引數,它會在你第一次建立和R/3的BW資料來源配置過程中生成。 

如果這個表出現錯誤,估計可以通過RSA13刪除source system來刪除,不過圖省事,我就直接改表了。  (會提示定義重複)
 

來自 “ ITPUB部落格 ” ,連結:http://blog.itpub.net/554557/viewspace-711238/,如需轉載,請註明出處,否則將追究法律責任。